  • T6.png
  • JSD20-10T6带logo带圆显正 - 副本.png
  • 神州烟道内芯浸锡铜无压形 - 副本(1757917496835).png
  • 神州烟道内芯无氧铜无压形(1757917498116).png

JSD20-10T6


Classification:

Key words:

Features

Natural exhaust system; High-efficiency heat exchanger design; Low water pressure start-up; Multiple safety protection devices; High efficiency & energy saving.

When the gate valve opens, the passage of fluid is completely free when the height of the gate lift is equal to 1:1 times the diameter of the valve, but this position cannot be monitored during operation. In actual use, it is the apex of the valve stem as a sign, that is, the position of open motionless, as its fully open position. In order to take into account the temperature changes in the phenomenon of locking, usually open to the apex of the position, and then back 1/2-1 turn, as the fully open position of the valve. Therefore, the valve's fully open position, according to the position of the gate (i.e., travel) to determine.

Related Products Inquire Now

Product Details


Features:
Natural Exhaust System: Relies on natural air convection to discharge combustion gases, ensuring safe operation.
High-Efficiency Heat Exchanger: Greatly enhances thermal efficiency and heating speed.
Low Water Pressure Start-Up: Operates reliably under various water supply conditions.
Multiple Safety Protection Devices: Provides comprehensive safety for users.
Digital Temperature Display & Intelligent Control: Enables real-time monitoring and maintains stable, comfortable water temperature.
Optimized Combustion System: Effectively reduces energy consumption for high efficiency and energy savings.

Specification   
Exhaust Type Flue Exhaust Type
Flue Pipe Dimmeter request  110
Chimney Type  Mild Steel electrophoresis
Heat Exchanger(kg) 2.2
Burnner (row)  5 Rows harmonica
Burnner Pipe Stainless Steel
Solenoide Valves ( 131B, 131A) 131B
Valve Type  common vlave
20mins timer 20min
Winter/Summer Switch YES
Display  YES
On/Off Switch N/A
Rated Electricity Supply  3VDC
Ignition Pin  Two pins
IgnitorType  pulse igniter
Cover  Painting
Feature   
Rated Heat Input(kw) 20
Rated Water Output ▲t=25°C (Lt.) 10
Nominal Heat Efficiency(≥)  84%
Nominal Gas Pressure (Pa)  LPG 2750Pa
NG  2000Pa
Start-up Water Pressure)(Mpa)  0.025
Over Heat Protection  YES
Flue Anti-Block Protection  NO
Over Water heat Pressure Protection  YES
Anti-Dry Burning Protection  YES
Flame Out Protection  YES
Electric Leakage Protection  NO
Package   
Product Dimension   550×330×185
Carton Dimension  650×400×250
Loading QTY 20GP/40GP/40HQ  431/892/1046

 

Gate valve closed, the sealing surface can only rely on media pressure to seal, that is, relying on the media pressure will be the sealing surface of the gate to the other side of the valve seat to ensure that the sealing surface of the seal, which is self-sealing. Most of the gate valve is a mandatory seal, that is, when the valve is closed, to rely on external forces to force the gate to the valve seat to ensure that the sealing surface of the seal.

Gate valve gate with the stem together for linear movement, called the lifting stem gate valve (also called open stem gate valve). Usually on the lifting stem has trapezoidal threads, through the nut at the top of the valve and the valve body on the guide groove, the rotary motion into a straight line, that is, the operating torque into the operating thrust.

Online Consultation

Security verification
Submit